The 94 series direct operated regulators are designed for high-pressure service and can be used on either on vapor or liquid applications. Their outlet pressure ranges from 3 to 100 psig.
The 94 series direct operated regulators are designed for high-pressure service and can be used on either on vapor or liquid applications. Their outlet pressure ranges from 3 to 100 psig.
High pressure regulators usually reduce tank pressure to an intermediate pressure for use by another regulator. They are also used for Final stage service on particular application, as high pressure burners as well as other medium sized commercial industrial applications.
Type 942Hp regulator is an adjustable high pressure regulator with a wide range of outlet pressures. It is not equipped with a limited relief valve.
Type 9482Hp regulator is an adjustable high pressure regulator with a wide range of outlet pressures. It is equipped with a limited relief valve.
Both types are equipped with a ¼” FNPT side outlet which is normally plugged and provides an opening for an outlet pressure gauge.
SPECIFICATIONS
Body and cover: aluminum
Diaphragm: reinforced
Supplying pressure: 25-250 PSI
Cover screws: stainless steel
Gas Type: propane
Setting point: inlet pressure 100PSI, 350000 BTU, outlet pressure 20PSI
Provided flows: flow based on inlet pressure 20 psig (1.38 bar) greater than outlet with 20% drop (in accordance with UL144 standard)